{"product_id":"victron-filax-2-transfer-switch-ce-230v-50hz-240v-60hz-sdfi0000000","title":"Victron Filax 2 Transfer Switch CE 230V\/50Hz-240V\/60Hz [SDFI0000000]","description":"\u003ch2\u003eVictron Filax 2 Transfer Switch CE 230V\/50Hz-240V\/60Hz\u003c\/h2\u003e\u003cp\u003eVictron transfer switches switch your AC loads automatically between two power sources, such as shore power, a generator and an inverter.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e230V shore power.\u003c\/strong\u003e Made for 230\/250 VAC shore power systems (Europe, the UK, Australia and many Caribbean and South American marinas). For standard US 120V shore power, call us and we'll point you to the 120V parts.\u003c\/p\u003e\u003ch3\u003eSpecifications (from Victron)\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: maximum continuous input voltage\u003c\/td\u003e\n\u003ctd\u003e260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate source: maximum continuous input voltage\u003c\/td\u003e\n\u003ctd\u003e260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC current rating\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad supplied by priority source\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: low frequency reverse switching threshold at 50Hz\u003c\/td\u003e\n\u003ctd\u003e47 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: low frequency reverse switching threshold at 60Hz\u003c\/td\u003e\n\u003ctd\u003e52 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: low frequency switching threshold at 50Hz\u003c\/td\u003e\n\u003ctd\u003e45 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: low frequency switching threshold at 60Hz\u003c\/td\u003e\n\u003ctd\u003e46 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: low voltage switching threshold\u003c\/td\u003e\n\u003ctd\u003e180 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: low voltage reverse switching threshold\u003c\/td\u003e\n\u003ctd\u003e188 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad supplied by alternate source\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum humidity (non-condensing)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e-4°F to 122°F (-20 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse switching delay\u003c\/td\u003e\n\u003ctd\u003e30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load transfer time and reverse transfer time\u003c\/td\u003e\n\u003ctd\u003e16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: high frequency switching threshold at 60Hz\u003c\/td\u003e\n\u003ctd\u003e68 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: high frequency switching threshold at 50Hz\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: high frequency reverse switching threshold at 60Hz\u003c\/td\u003e\n\u003ctd\u003e63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source: high frequency reverse switching threshold at 50Hz\u003c\/td\u003e\n\u003ctd\u003e56 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriority source fault\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection category\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eLight grey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmission \/ Immunity\u003c\/td\u003e\n\u003ctd\u003eEN 55014-1,EN 55014-2,EN-IEC 61000-3-3,EN-IEC 61000-6-1, EN-IEC 61000-6-2,EN-IEC 61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eEN-IEC 60335-1,EN-IEC 60335-2-29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e4.7 x 10 x 3 in (120 x 255 x 75 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lb (0.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years (Victron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron part number\u003c\/td\u003e\n\u003ctd\u003eSDFI0000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC \/ EAN\u003c\/td\u003e\n\u003ctd\u003e8719076025672\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eMalaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Datasheet-and-installation-manual-Filax-2_the-ultra-fast-transfer-switch_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFilax 2 (datasheet)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/transfer-switches\/filax-2\" target=\"_blank\" rel=\"noopener\"\u003eVictron product page (manuals, drawings, certificates)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrom Victron\u003c\/h3\u003e\u003cp\u003eThe Filax has been designed to switch sensitive loads, such as computers or modern entertainment equipment from one AC source to another. The priority source typically is the mains, a generator or shore power. The alternate source typically is an inverter. With its switching time of less than 20 milliseconds, sensitive loads will continue to operate without disruption. The Filax is not intended to supply high power household equipment like washing machines or electric motors.\u003c\/p\u003e\u003cp\u003e\u003cspan lang=\"EN-AU\"\u003eThe Filax 2 is available in two models:\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e230V\/50Hz-240V\/60Hz\u003c\/li\u003e\n\u003cli\u003e110V\/50Hz-120V\/60Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBuying from OnBoard\u003c\/h3\u003e\u003cp\u003eWe install Victron systems on boats in Marathon and the Florida Keys. Not sure it's the right part for your system? Call \u003ca href=\"tel:+13059984300\"\u003e305-998-4300\u003c\/a\u003e or email \u003ca href=\"mailto:contact@onboardmarinegoods.com\"\u003econtact@onboardmarinegoods.com\u003c\/a\u003e and we'll help you pick it and plan the wiring before you buy. Local pickup is available at \u003ca href=\"\/pages\/location\"\u003eour shop on US-1 in Marathon\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.P65Warnings.ca.gov\" target=\"_blank\" rel=\"noopener\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50815257444527,"sku":"SDFI0000000-VIC","price":287.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1680\/8011\/files\/image_093faa3e-5a6d-4d4f-8e74-52b95fb1e1b0.jpg?v=1793748749","url":"https:\/\/onboardmarinegoods.com\/products\/victron-filax-2-transfer-switch-ce-230v-50hz-240v-60hz-sdfi0000000","provider":"OnBoard Rigging","version":"1.0","type":"link"}