{"product_id":"victron-energy-meter-vm-3p5a-rel200320100","title":"Victron Energy Meter VM-3P5A [REL200320100]","description":"\u003ch2\u003eVictron Energy Meter VM-3P5A\u003c\/h2\u003e\u003cp\u003eAn energy meter that measures AC power and energy and reports it to a Victron GX device, for ESS, PV inverter and grid monitoring.\u003c\/p\u003e\u003ch3\u003eSpecifications (from Victron)\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVE.Can communication port\u003c\/td\u003e\n\u003ctd\u003eTwo RJ45 connectors (VE.Can terminators included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet communication port\u003c\/td\u003e\n\u003ctd\u003eOne RJ45 connector, Modbus UDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Connection\u003c\/td\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh rate\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSelf-powered supply via N-L1-L2-L3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumption in VA\u003c\/td\u003e\n\u003ctd\u003e3.5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumption in W\u003c\/td\u003e\n\u003ctd\u003e1.85 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput AC voltage range L - N\u003c\/td\u003e\n\u003ctd\u003e85–265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput AC voltage range L - L\u003c\/td\u003e\n\u003ctd\u003e150–460 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent connection\u003c\/td\u003e\n\u003ctd\u003eVia current transformers (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50Hz or 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Transformer connection\u003c\/td\u003e\n\u003ctd\u003ePluggable screw terminals (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection category\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003epolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eBlue (RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003e-4°F to 158°F (-20 to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eCat. III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e14°F to 131°F (-10 to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity (non-condensing)\u003c\/td\u003e\n\u003ctd\u003e90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains Voltage Fluctuations\u003c\/td\u003e\n\u003ctd\u003e±0,1 Vin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor or outdoor usage\u003c\/td\u003e\n\u003ctd\u003eIndoor only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eEN-IEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e3.5 x 2.8 x 2.3 in (90 x 71 x 59 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 lb (0.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years (Victron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron part number\u003c\/td\u003e\n\u003ctd\u003eREL200320100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC \/ EAN\u003c\/td\u003e\n\u003ctd\u003e8719076072539\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Datasheet-Energy-Meters-Selection-Guide-EN-.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSelection Guide - Energy Meters (datasheet)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Datasheet-Energy-Meter-VM-3P5A-+-VM-3P75CT-EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eVictron Energy Meters VM-3P5A \u0026amp; VM-3P75CT (datasheet)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/meters-and-sensors\/energy-meter\" target=\"_blank\" rel=\"noopener\"\u003eVictron product page (manuals, drawings, certificates)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrom Victron\u003c\/h3\u003e\u003cp\u003e\u003cspan lang=\"EN-US\"\u003eEnergy Meters are typically used in an Energy Storage System, \u003c\/span\u003eto measure the power and energy of the entire application at the distribution box and minimises energy import or export to the grid. They can also be used to measure the output of a PV inverter or AC loads and display the data on GX devices such as \u003cspan\u003ethe\u003c\/span\u003e Cerbo GX or Ekrano GX and the VRM Portal.\u003c\/p\u003e\u003cp\u003eThere are several models available from Victron:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVictron VM-3P75CT energy meter (Ethernet and VE.Can - for three-phase and split-phase, uses supplied CTs, max. 80A per phase)\u003c\/li\u003e\n\u003cli\u003eVictron VM-3P5A energy meter (Ethernet and VE.Can - for three-phase and split-phase)\u003c\/li\u003e\n\u003cli\u003eET112 (RS485 - for single-phase max 100A)\u003c\/li\u003e\n\u003cli\u003eET340 (RS485 - for three-phase max. 65A)\u003c\/li\u003e\n\u003cli\u003eEM24 Ethernet (Ethernet - for three-phase max. 65A)\u003c\/li\u003e\n\u003cli\u003eEM540 (RS485 - for three-phase max. 65A)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor more information, please see the Selection Guide - Energy Meters PDF below.\u003c\/p\u003e\u003ch3\u003eBuying from OnBoard\u003c\/h3\u003e\u003cp\u003eWe install Victron systems on boats in Marathon and the Florida Keys. Not sure it's the right part for your system? Call \u003ca href=\"tel:+13059984300\"\u003e305-998-4300\u003c\/a\u003e or email \u003ca href=\"mailto:contact@onboardmarinegoods.com\"\u003econtact@onboardmarinegoods.com\u003c\/a\u003e and we'll help you pick it and plan the wiring before you buy. Local pickup is available at \u003ca href=\"\/pages\/location\"\u003eour shop on US-1 in Marathon\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.P65Warnings.ca.gov\" target=\"_blank\" rel=\"noopener\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50715832549551,"sku":"REL200320100-VIC","price":151.3,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1680\/8011\/files\/image_81461b95-8372-4176-910e-84cd8ca2a32f.png?v=1792622019","url":"https:\/\/onboardmarinegoods.com\/products\/victron-energy-meter-vm-3p5a-rel200320100","provider":"OnBoard Rigging","version":"1.0","type":"link"}